            • Frozen Hair Grinder
            • DHFSTPRP-HR24
            • Frozen Hair Grinder
            • After cleaning and frozen grinding, hair samples are extracted using the methanol ultrasound method and detected using liquid chromatography-tandem mass spectrometry with multiple reaction monitoring
            DHFSTPRP-HR24 frozen hair grinder utilizes a special vertical up-and-down integrated vibration mode, which achieves the desired grinding effect quickly through the high-frequency reciprocating vibration, impact, and shear of grinding beads (zirconia, steel, glass, ceramic).
            Product Introduction
            DHFSTPRP-HR24 Frozen Hair Grinder utilizes a special vertical up-and-down integrated vibration mode, which achieves the desired grinding effect quickly through the high-frequency reciprocating vibration, impact, and shear of grinding beads (zirconia, steel, glass, ceramic). This results in samples that are more fully ground, more uniform, with better sample repeatability, and no cross-contamination between samples. Combined with the judicial appraisal technical specification SF/Z JD0107025-2018 "Liquid Chromatography-Tandem Mass Spectrometry Method for the Detection of 15 Drugs and Their Metabolites in Hair", it can quickly detect common drugs (such as heroin, methamphetamine, ketamine, ecstasy, marijuana) in hair on-site. The detection limits for various drugs have reached the requirements of the "Specifications for Hair Sample Testing of Drug-Involved Personnel" issued by the Ministry of Public Security. Since its launch, this product has been widely recognized in the industry and has received multiple innovations, as well as the acceptance report of the Key Laboratory of Toxicological Analysis of the Public Security Ministry of Beijing Public Security Bureau.
            This instrument is a recommended product in the judicial appraisal technical specification SF/Z JD0107025-2018 "Liquid Chromatography-Tandem Mass Spectrometry Method for the Detection of 15 Drugs and Their Metabolites in Hair".


            Principle of the Product
            After cleaning and frozen grinding, hair samples are extracted using the methanol ultrasound method and detected using liquid chromatography-tandem mass spectrometry with multiple reaction monitoring (MRM) mode. Qualitative analysis is conducted by comparing the retention time, mass spectral characteristic fragment ion peaks, and relative abundance ratios of the ion pairs with those of the parallel blank samples and spiked samples for control purposes.


            Product Features
            ○ High efficiency grinding
            Simultaneously process 24 hair samples for rapid on-site grinding. The grinding equipment has a built-in program controller, making it easy to operate. It also provides feasible solutions for community drug rehabilitation and special personnel monitoring.
            ○ Low-temperature grinding
            The temperature of the frozen grinding can be customized and adjusted to protect the components of the sample at low temperature and avoid destruction of the sample components.
            ○ Professional grinding
            The instrument has completed nearly a thousand real sample tests in judicial centers and drug enforcement teams in Beijing, Ningbo, Sichuan, Hunan, Shanghai and other places. The positive detection rate is as high as 99%, effectively avoiding false positive interference caused by drug use.


            Product Applications
            Sample for Grinding:
            1. Plant Tissues: roots, stems, leaves, flowers, fruits, seeds, etc.
            2. Animal Tissues: brain, heart, lung, stomach, liver, thymus, kidney, intestine, lymph nodes, muscle, bones, etc.
            3. Fungi and Bacteria: yeast, E. coli, etc.
            4. Food and Medicine: various food, pills, etc.
            5. Volatile Samples: coal, oil shale, wax products, etc.
            6. Plastics and Polymers: PE, PS, textiles, resins, etc.
            ·Nucleic Acid/Protein Extraction
            Low-temperature grinding of samples can effectively inhibit nucleic acid degradation and preserve protein activity.
            ·Analysis of Active Pharmaceutical Ingredients
            There are often significant differences between isomers of drug active ingredients. Low-temperature grinding can prevent molecular degradation due to pressure and heat.
            ·Reducing Sample Volatility
            Low-temperature grinding can significantly reduce sample volatility and more completely retain the content of sample components.
            ·Grinding Tough/Hard Samples
            For hard-to-grind samples such as tough plastics, high-strength plastics, and resins, low-temperature grinding can greatly improve grinding efficiency and effectiveness.
            homogenizer_tissuelyser
            DHFSTPRP-HR24 frozen hair grinder adopts a special vertical up-down integrated vibration mode, which achieves rapid grinding of samples through the high-frequency reciprocating vibration, impact, and shear of grinding beads (zirconia, steel, glass, ceramics). This results in more thorough and uniform grinding of samples, better sample reproducibility, and no cross-contamination between samples.


            Forensic Appraisal Technical Specification SF/Z JD0107025-2018 "Liquid Chromatography-Tandem Mass Spectrometry Detection Method for 15 Drugs and Metabolites in Hair"
            1. Sample Preparation
            1.1 Case Sample
            The hair sample is washed twice with an appropriate amount of water and acetone by shaking, then dried and cut into approximately 1mm segments. The hair segments are then frozen and ground to a powder in a cryogenic grinder. Weigh 20mg of hair powder, add 1.0mL internal standard methoxamine standard working solution (methoxamine 1ng/mL), perform ice bath sonication for 30 minutes, centrifuge, transfer the supernatant, and dry at 60°C with air flow (or a dry nitrogen blower). The residue is re-dissolved with 100μL methanol for instrument analysis.
            1.2 Blank Sample
            Take 20mg of blank hair sample, add 1.0mL internal standard methoxamine standard working solution (methoxamine 1ng/mL), and follow the same extraction procedure as described in 6.1.1 for case samples.
            1.3 Spike Sample
            Take 20mg of blank hair sample, add the suspected target compound reference material that appears in the case sample, add 1.0mL internal standard methoxamine standard working solution (methoxamine 1ng/mL), and follow the same extraction procedure as described in 6.1.1 for case samples.
            homogenizer_tissuelyser


               
            Multiple operation, good effect Highly efficient and fast operation can complete the grinding of 2x24, 2x48, 4x96 samples within 1 minute. It saves time and effort, and has small differences between batches and within batches. The extracted protein has a higher activity and longer nucleic acid fragments.
            No cross-contamination The sample tubes are in a fully enclosed state during the crushing process, and disposable centrifuge tubes and beads can be used. The samples are kept intact in the tubes, avoiding cross-contamination between samples and external contamination.
            Easy operation 1. Built-in program controller, which can set parameters such as grinding time and vibration frequency of the rotor;
            2. User-friendly operating interface.
            Good stability 1. Adopting vertical oscillation mode for more thorough grinding and better stability;
            2. During instrument operation, the noise is less than 55dB, which will not interfere with other experiments or instruments.
            Convenient for low-temperature operation When a low-temperature grinding environment is required, the adapter with the sample can be immersed in liquid nitrogen for 1-2 minutes, and then moved to the main unit for quick fixation to start grinding without the need for re-freezing, saving liquid nitrogen.
            Good repeatability Setting the same program for the same tissue sample can obtain the same grinding effect. The working time is short, and the sample temperature does not rise.


            Technical Parameters  
            Application Fields: Hair grinding, tissue grinding, homogenization, cell lysis, material dispersion, preparation, sample mixing, oscillation, etc.
            Processing Capacity: Maximum processing capacity of 24 samples at the same time within 15 seconds, with built-in compressor for cooling
            Compatible Sample Tubes: 24*(0.2-0.5mL) /24*2mL /6*(7-15)mL /2*25mL /2*50mL, and various specifications of grinding tubes can be customized
            Display: Touch screen display for convenient and intuitive operation
            Data Storage: Up to ten sets of experimental data can be stored, and different experimental samples are pre-set such as animal heart, spleen, lung, kidney, bone, skin, hair, etc.
            Cycle Mode: According to the set experimental parameters, the device can cycle through several pre-set parameter settings to further reduce human interference
            Anti-Vibration Principle: Innovative anti-vibration principle based on the German "schleifen-1" working mode, as well as the innovative three-dimensional motion of the grinding beads in the vertical, horizontal and rocking directions, to ensure maximum sample processing and instant crushing effect
            Maximum Feed Size: No specific requirements, can be adjusted according to the adapter
            Cooling function: Yes, adjustable from -30°C to 37°C
            Temperature control accuracy: +0.5°C
            Open lid operation protection: Electromagnetic lock
            Final particle size: ~5µm
            Number of grinding platforms: (can accommodate number of grinding jars) > 2
            Fastening device: With automatic centering
            Homogenization speed: 0-70 Hz/second, working time: 0 seconds to 99 minutes, user can set it
            Grinding ball diameter: 0.1-30mm
            Grinding ball material: Alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand
            Acceleration: Reaches maximum speed within 2 seconds
            Deceleration: Reaches lowest speed within 2 seconds
            Noise level: <55db
            Grinding mode: Wet grinding, dry grinding, and low temperature grinding are all available
            Temperature control can be additionally equipped: Has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigeration
            Adapter material: Polytetrafluoroethylene, alloy steel
            Safety instructions: Fastening device with automatic centering, safety lock during operation, full protection
            Grinding kit material: Hard alloy, polytetrafluoroethylene (PTFE), zirconia
            Dimensions: 630*300*480mm
            Weight: 58 kg


            Single Page - Color Page    
            Name: Author: Action:
            Frozen Hair Grinder DHFSTPRP-HR24 homogenizer Download


            Related products  
            Name: Model:
            Rapid hair grinding instrument DHFSTPRP-HP24
            Frozen Hair Grinder DHFSTPRP-HR24
            portable rapid hair grinder DH-2019
            Product List
            DHFSTPRP-HR24 Unit
            Host Machine Unit
            Adapters set
            Cooling Adapter Set
            Zirconia Grinding Bead No.5 Piece
            Zirconia Grinding Bead No.3 Piece
            Special Grinding Tube Piece
            Special Bead Loading Gun Set
            Description
            1
            ?2ml,1(2 in 1)
            ?2or?1.5ml,1(2 in 1)
            1000(2 in 1)
            1000(2 in 1)
            200
            1(Optional)
            紧身短裙女教师波多野